AIR CONDITIONER PSYCHROMETRIC LAB

The test room can be used to determine the performance of domestic air conditioner by using air enthalpy differencetest method,It consists of indoor side (1 room), outdoor side (1 room), air handling unit, refrigerating machine, airflow meter, power panel,computerized automatic control system and data acquisition system etc.

1.Specification 

       
Indoor side 
Outdoor side 
Temperature (°C)
10~50
-20~60
Relative humidity (%RH)
35~90
Air flow measuring chamber
Air flow rate(CFM)
200~2000
-
Type
Movable
-
Static pressure(Pa)
-50 to 500
-
Quantity
1
Thermocouple(-50~150°C) (Channel)
20
20
Refrigerant pressure(channel)
-
2
Power meter(WT333E) (CH)
1
3 phase, 45kVA
Refrigerant
R22/R410a/R32/R290/R134a
Note:The specification can be customized based on customer’s requirements.

2.Standards and regulation

GB 7725-2010Room air conditioner
ISO 5151-2017   Non-ducted air conditioners and heat pumps -- Testing and rating for performance
ISO 13253-2017  Non-ducted air conditioners and heat pumps -- Testing and rating for performance

3.Test items

Rated cooling/heating capacity
Maximum cooling/heating performance test
Minimum cooling/heating performance test 
Automatic defrost performance test
Freeze-up performance test 
Condensate control and enclosure sweat performance test
COP and SEER